1000V 1200V 1500V T1 Type SPD 4p Solar Surge Arrester DC Surge Protective Device with High Voltage Protection

Product Details
Customization: Available
Type: T1
Max Discharge: 12.5ka Current
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2005

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2014-03-26
Number of Employees
41
  • 1000V 1200V 1500V T1 Type SPD 4p Solar Surge Arrester DC Surge Protective Device with High Voltage Protection
  • 1000V 1200V 1500V T1 Type SPD 4p Solar Surge Arrester DC Surge Protective Device with High Voltage Protection
  • 1000V 1200V 1500V T1 Type SPD 4p Solar Surge Arrester DC Surge Protective Device with High Voltage Protection
  • 1000V 1200V 1500V T1 Type SPD 4p Solar Surge Arrester DC Surge Protective Device with High Voltage Protection
  • 1000V 1200V 1500V T1 Type SPD 4p Solar Surge Arrester DC Surge Protective Device with High Voltage Protection
  • 1000V 1200V 1500V T1 Type SPD 4p Solar Surge Arrester DC Surge Protective Device with High Voltage Protection
Find Similar Products
  • Overview
  • Product Paramenters
  • Products Description
  • Recommend Products
  • About Us
  • Exhibition
  • Certifications
  • FAQ
  • Packing and Shipping
Overview

Basic Info.

Model NO.
AF-LY1-C
Nominal Voltage
600DC
Product Name
DC Surge Protector
OEM
Yes
Degree Protection
IP20
Operation
Temperature -40 To80
Normal Discharge
12.5ka Current
Pole
1p-4p
Trademark
AMPPAL
Origin
Zhejiang, China

Product Description

1000V 1200V 1500V T1 Type SPD 4p Solar Surge Arrester DC Surge Protective Device with High Voltage Protection
Product Paramenters
 
SPD is used to protect all kinds of electrical equipment in the power system from lightning over-voltage, operation over-voltage,power frequency transient over-voltage impact damage to an electrical appliance
The electrical circuit or communication lines because of outside interference peak current or voltage suddenly, the surge protector can in a very short time conducting shunt, so as to avoid damage to other equipment surge in the loop Installed front of
inverter input and back of inverter output Installed in Parallel the spd is installed in the electric circuit with parallel, the first to play a protective role, the response time in the 25 to 50 nanosecond

Advantage
First factory produce 1500V SPD, approved TUV certificate at EN50539-11 standard.
Every pole achieve 1500V, 1200V, 1000V, 500V.
PPT material cover. Anti flame.
Use Longke chip from Taiwan. Material Zinc oxide.
With specific thermal disconnects and failure indicator(visual indicator/ optional): green-good, red-replace
Remote control: with signal contact Plug-in module
Life: 50 times
SUP2-PV series surge protector
SUP2-PV
Normal PV system voltage
1000V
1200V
1500V
MCOV
1170V DC
1200V DC
1500V DC
Max system discharge current
40ka
30ka
30ka
Voltage protection level
≤4kv
≤4.5kv
≤4.5kv
Voltage protection
≤3.5kv
≤4kv
≤4kv
level at 5ka
Integrated Fuse
30ka/100v dc
30ka/1200v dc
30ka/1500v dc
breaking capacity
/interrupting rating
Technology
Short-current interription overload protection
Operating temperature range
-40ºC + 80ºC
Normal discharge current
12.5ka
Response time
<25ns
Operating state/fault indication
green(good) Red(replace)
Conductor rating
Minimum
60/75ºC 1.5mm2 /14AWG Solid/ Flexible
and cross-sectionalarea
Maximum
60/75ºC 35mm2 /2AWG Standards /25mm2/ 4AWG Flexible
Mounting
35mm din rail per EN 60175
Enclosure material
UL 94V0 thermoplactic
Degree of protection
IP20
Capacity
3 Modules, din 43880
Standards information
IEC 61643-11 Type2, IEC 61643-1 Class II
Product warranty
Five years
 
Products Description
1000V 1200V 1500V T1 Type SPD 4p Solar Surge Arrester DC Surge Protective Device with High Voltage Protection
1000V 1200V 1500V T1 Type SPD 4p Solar Surge Arrester DC Surge Protective Device with High Voltage Protection
Recommend Products
 
1000V 1200V 1500V T1 Type SPD 4p Solar Surge Arrester DC Surge Protective Device with High Voltage Protection
 
About Us
1000V 1200V 1500V T1 Type SPD 4p Solar Surge Arrester DC Surge Protective Device with High Voltage Protection
Zhejiang Anfu New Energy Technology Co., Ltd. is located in Yueqing Economic Development Zone Zhejiang Province. lt is designated by the Yueging city government as a Smart Manufacturing Technology Zone Center Demonstration Enterprise. In 2020, we partnered with FANUC Robot Co.. Ltd. to establishan inteligent robot workshop. The company employs over 300 individuals, with 15% of them being senior professi onal and technical personnel. Our comp any possesses robust product research and development capabilities, as well as advanced production technology and equipment.We have been honored by the Yueging Science and Technology Bureau with the titles of "TechnologyR&D Center for Municipal Enterprises" and "Patent Demonstration Enterprise Unit." Additionally, we haveobtained lSO 9001:2000 National Quality Management System Standard certification.
1000V 1200V 1500V T1 Type SPD 4p Solar Surge Arrester DC Surge Protective Device with High Voltage Protection
1000V 1200V 1500V T1 Type SPD 4p Solar Surge Arrester DC Surge Protective Device with High Voltage Protection
1000V 1200V 1500V T1 Type SPD 4p Solar Surge Arrester DC Surge Protective Device with High Voltage Protection
Exhibition
1000V 1200V 1500V T1 Type SPD 4p Solar Surge Arrester DC Surge Protective Device with High Voltage Protection
Certifications
1000V 1200V 1500V T1 Type SPD 4p Solar Surge Arrester DC Surge Protective Device with High Voltage Protection
FAQ
What is your terms of payment?
A: L/C, T/T, D/P, Western Union, Paypal, Money Gram
Do you test all your chargers before shipping?
A: All major components are tested before assembly and each charger is fully tested before shipped
Can I order some samples? How long?
A: Yes, and usually 7-10 days to production and 7-10 days to express.
How long to fully charge a car?
A: To know how long to charge a car, you need to know the OBC(on board charger) power of the car, the car battery capacity, the charger power. The hours to fully charge a car =battery kw.h/obc or charger power the lower one. For e.g, the battery is 40kw.h, obc is 7kw, charger is 22kw, the 40/7=5.7hours. If the obc is 22kw, then 40/22=1.8hours.
Are you Trading Company or manufacturer?
A: We are professional EV charger manufacturer.
Packing and Shipping
1000V 1200V 1500V T1 Type SPD 4p Solar Surge Arrester DC Surge Protective Device with High Voltage Protection

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Send Inquiry
Chat Now